Methamphetamine Presence Test
$12.95
This is a rapid test for the detection of Methamphetamine on surfaces and in solids at a cut-off of 500ng/ml. If you want to check a sample for the presence of Methamphetamine this is the test for you. If you want to test a surface (wall, desk, bench etc) for the presence of Methamphetamine this will be test you need.
Package contents:
- 1 Methamphetamine Rapid Test
- Instructions and product insert
DIRECTIONS FOR USE:
- Allow the test and/or controls to reach room temperature (15-30°C) prior to testing. Remove the test panel from the sealed pouch and use it as soon as possible.
SURFACES:
- Remove the panel cap and wipe with the panel over the surface in which the drugs are suspected.
- With the arrow pointing toward the water, immerse the test panel vertically in the water for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
- Wait for the coloured lines to appear, read the results at 5 minutes. Do not interpret the result after 10 minutes.
FOR SOLIDS:
- Prepare specimen collection containers and solid sample.
- Pour solid sample into the specimen collection containers.
- At least 1mg solid diluted with 5mL water (1 mineral water bottle cap = 5mL). Shake to mix well.
- Remove the panel cap, with the arrow pointing toward the water immerse the test panel vertically in the diluted specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
- Wait for the coloured lines to appear, read the results at 5 minutes and do not interpret the result after 10 minutes.
FOR URINE:
- Collect urine in a clean and dry container.
- Remove the panel cap, with the arrow pointing toward the water immerse the test panel vertically in the specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
- Wait for the coloured lines to appear, read the results at 5 minutes and do not interpret the result after 10 minutes.
FOR LIQUIDS:
- Prepare specimen collection containers and liquid sample.
- Pour one to three drops of suspicious liquid into 5mL water (1 mineral water bottle cap = 5mL). Shake to mix well.
- Remove the panel cap, with the arrow pointing toward the specimen, immerse the test panel vertically in the specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
- Wait for the coloured lines to appear, read the results at 5 minutes and do not interpret the result after 10 minutes.
INTERPRETATION OF RESULTS:
(Please refer to the illustration above)
NEGATIVE:* A coloured line appears in the Control region (C) and coloured lines appear in the Test region (T). This negative result means that the concentrations in the sample are below the designated cut-off levels for a particular drug tested.
*NOTE: The shade of the coloured lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.
POSITIVE: A coloured line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the sample is greater than the designated cut-off for a specific drug.
INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.